Wiring 2 door contacts or floor contacts through one junction box with double EOL

6 April 2026 · updated 25 October 2026 · Theo

FRLire cette fiche en français
Schéma câblage de 2 Sabot : DO sur une BR
Click to enlarge
●
Difficulty: Beginner
⏱️
Reading time: ~4 min

When two floor contacts or door contacts (DO) are close to each other (double door, double-leaf gate…), they can be connected to a single junction box (BR on the diagram) and use only one zone on the panel.

The alarm pairs of both contacts are put in series in the junction box, and so are the tamper pairs, which simplifies the wiring and reduces the number of zones used.

The panel reads R1 in normal state and R1 + R2 as soon as a contact opens. The principle, the ranges used by each panel and the other ways of wiring several contacts on one zone are covered in the guide Double EOL zone balancing.

⚡
The essentials in 30 seconds
  • Two floor contacts or door contacts with 4 wires each, a single double EOL zone on the panel.
  • In the junction box: alarm pairs in series with R2 (1 kΩ) in parallel and R1 (1 kΩ) in series, tamper pairs in series.
  • Ohmmeter: ≈ 1 kΩ with both contacts closed, ≈ 2 kΩ as soon as one contact opens, ∞ Ω if the cable is cut.
  • One zone for two contacts: no way of knowing which one triggered.

What you need

Item Specification
Contacts2 × floor contact or door contact, 4 wires each
Zone typeDouble EOL: 1 zone for 2 contacts
EOL resistors2 × 1 kΩ (in the junction box)
Junction boxStandard junction box
Compatible withGalaxy GD-48 / GD-96 / GD-264 / GD-520 / TIL panel
Power supplyPassive: no power required

Ohmmeter reference values

State Measured value
Both contacts closed (normal)≈ 1 kΩ
One contact open (alarm)≈ 2 kΩ
Cable cut (tampering)∞ Ω (open circuit)
Tamper0 Ω (continuity)

Identifying the wires, per contact

Cables Role
Alarm pair 1 + alarm pair 2“Alarm” pair: EOL circuit
Tamper pair 1 + tamper pair 2“Tamper” pair: continuity
ℹ️
Identify both pairs on each contact before wiring
  • Closed ≈ 1 kΩ / open ≈ 2 kΩ: alarm pair.
  • Continuity (0 Ω): tamper pair.

Wiring 2 contacts in one junction box

In the junction box, the cables of both contacts are brought together:

Wiring diagram of two floor contacts or door contacts on a single junction box: alarm pairs in series with two 1 kΩ resistors, tamper pairs in series, outputs to the panel in Blue (alarm) and Light blue (tamper)

Click to enlarge

1
Alarm pairs in series
The alarm pairs of contact 1 and contact 2 are joined end to end in the junction box, with R2 (1 kΩ) in parallel across the whole and R1 (1 kΩ) in series. If either contact opens, the zone triggers.
2
Tamper pairs in series
The tamper pairs of contact 1 and contact 2 are joined end to end. The panel supervises the continuity of the whole.
3
Junction box output to the panel
Only 2 wires go to the panel zone: one on the alarm contacts side (e.g. Blue), the other on the tamper side (e.g. Light blue).
!
Between the contacts and the junction box
Since the resistors are in the junction box, the alarm pairs between the contacts and the junction box are not supervised like the rest of the line: a cut there gives 2 kΩ, hence an alarm, and a short circuit there masks the opening of the contact. The tamper pairs, for their part, trigger the tamper if they are cut.

Points to watch

!
Identify the pairs
Identify the pairs carefully on each contact before wiring: swapping the alarm and tamper pairs would leave the zone not working.
!
One zone for two contacts
This configuration uses a single zone for two contacts: when it triggers, the panel cannot tell which of the two did. If you need to tell them apart, use two separate zones.
✕
R1 and R2 in series
Never put R1 and R2 in series: the normal value would be 2 kΩ instead of 1 kΩ and the panel will not recognise the zone.
ℹ️
Why use a junction box
It keeps all the connections in one accessible place, which makes diagnosis and maintenance easier.

Sources: Galaxy Dimension installation manual (Honeywell), zone wiring · TILLYS CUBE, TILLYS NG and remote modules register list (GR-10005-FR, in French), § 3.2.

BR: junction box
Keeps all the connections of both contacts in one accessible place, which makes diagnosis and maintenance easier.
AP: tamper (“auto protection”)
Pair of the cable dedicated to its own supervision: continuity 0 Ω. Both tamper pairs are put in series in the junction box.
eol-doubleboite-raccordement