ATLS THE VOICE EXT siren: wiring and programming
15 August 2026 · updated 25 October 2026 · Theo
FRLire cette fiche en français
The THE VOICE EXT is an external siren with a voice speaker made by ATLS, ALTEC range. It combines three functions: an alarm tone compliant with the French standard NF C 48-265, an LED strobe, and voice message playback.
On a standard intruder installation, a single input is wired: SIR. It receives the trigger command from the siren output of the panel.
The message inputs IN1 to IN4 and the signalling input 1/0 are for other uses, mainly PPMS (French lockdown and emergency plans for schools). They are not covered here.
The physical connection is limited to five conductors. The difficulty lies elsewhere: the SIR input must be set to match exactly the logic of the panel output. A polarity or mode error gives a siren in permanent alarm as soon as it is powered up.
- Power on
DC 12-24, range 10 to 30 V DC. Optional 12 V – 2 Ah lead-acid battery. SIRinput set at the factory toPO+/NC: +12 V at rest, 0 V or open circuit in alarm.- Default tone of an EXT:
S02.S01is the indoor tone, not to be confused with it. - Tamper
AP TAMPER: normally closed loop, in series on the panel tamper loop. - Strobe set at the end of the
SIRmenu:FL0disabled,FL1enabled.
Connection terminals
All the voltages on the terminals are SELV (safety extra-low voltage) as defined by EN 60950.
| Terminal | Function | Factory setting |
|---|---|---|
SIR |
Triggers the alarm tone | PO+ / NC |
IN1 to IN4 |
Trigger messages 1 to 4 | PO+ / NC |
1/0 |
On / off signalling. One message on activation, a second one on reset | PO+ / NC |
BLK |
Switches a +12 V while a message is playing, to block the other sirens on the site | — |
A B C D |
RS-485 master / slave bus: commands and audio files | — |
DC 12-24 |
External power supply 10 to 30 V DC | — |
AP TAMPER |
Normally closed tamper loop | NC |
OFF. The inputs are only wired on the master unit. On a slave (DIP 1 ON), the inputs change role: connected to 0 V, they block the matching message instead of triggering it.Power supply, battery and tamper
The supply range is 10 to 30 V DC. The siren can therefore be connected either to a 12 V panel or to a 24 V power supply. The SICB charging circuit manages the battery over the whole range.
| Configuration | Max current on DC 12-24 |
DIP 3 position |
|---|---|---|
| With internal battery | 500 mA with a flat battery | OFF |
| Without internal battery | 2 A | ON |
The backup battery is a 12 V – 2 Ah lead-acid battery, not supplied. With internal batteries, a 2 A charger powers up to four sirens wired in series, minimum conductor size 0.5 mm².
The tamper covers cover opening and removal from the wall. It relies on a microswitch rated 12 V DC / 5 A. The AP TAMPER output is wired in series on the panel tamper loop.
SIR input at a floating potential. Triggering becomes unpredictable.Wiring the SIR input
Five conductors are enough: two for power, one for the command, two for the tamper.
| Siren terminal | Panel destination |
|---|---|
DC 12-24 (+) | Permanent +12 V auxiliary output |
DC 12-24 (−) | Common 0 V |
SIR | External siren output |
AP TAMPER | Tamper loop, in series |
Click to enlarge
Polarity and mode
The SIR input is set on two independent criteria. The polarity defines which level counts: PO+ or PO-. The mode defines the direction of the change of state: NC or NO.
Combined, they give four cases.
| Polarity | Mode | Rest state | Alarm state |
|---|---|---|---|
PO+ / NC |
Factory | 12 V DC | 0 V DC or nothing |
PO+ / NO |
— | 0 V DC or nothing | 12 V DC |
PO- / NC |
— | 0 V DC | 12 V DC or nothing |
PO- / NO |
— | 12 V DC or nothing | 0 V DC |
The difference between “0 V” and “nothing” is decisive. Nothing means a high-impedance state, typically an open-collector output without a pull-up.
Direct consequence: an output that applies no potential at rest is not suitable for PO+ / NC. This setting requires a clean +12 V.
| Electrical parameter | Value |
|---|---|
| Command threshold in negative polarity | < 2 V DC |
| Command threshold in positive polarity | > 3 V DC |
| Maximum permissible voltage | 30 V DC |
| Current drawn | < 0.1 mA |
SIR input is a logic input. It draws less than 0.1 mA. Power goes exclusively through DC 12-24. Connecting the power supply to the siren output destroys the output stage on the first trigger: the current drawn in alarm reaches 1.2 A.Connection depending on the panel
The setting to use depends on one thing only: the electrical behaviour of the panel siren output. The reliable method is to measure it, rather than assume it.
SIR accordingly.The table below gives the most common configurations by brand. It is a starting point, not a certainty: the type and polarity of the outputs remain programmable on most panels.
| Panel | Output used | Behaviour | SIR setting |
|---|---|---|---|
| Honeywell Galaxy — G2, G3, Dimension, Flex | Output 1001, external sirens. Transistor output, open collector switching to 0 V |
+12 V at rest, 0 V in alarm | PO+ / NC — factory setting, nothing to change |
| Vanderbilt SPC | Output programmed as an external siren type | Depends on the output type declared in the configuration | To be determined by measurement |
| TIL Technologies — TILLYS, CUBE | Command register pointing to an ML module output, for example XA0102 |
Relay: dry contact. Transistor: switching to 0 V | Depending on the module output type |
| Relay output — any manufacturer | Potential-free COM / NC / NO contact |
Set by the chosen wiring | PO+ / NC with COM on +12 V |
Dry-contact output
A relay output applies no potential. It is the wiring that builds the logic expected by the input.
To keep the factory setting PO+ / NC: connect the common COM to +12 V, and the normally closed contact of the relay to SIR. At rest, the siren receives +12 V. On activation, the contact opens and the input goes high-impedance, which matches the “0 V or nothing” state of the alarm condition.
OFF position switches the transistor outputs to pure open collector and removes the internal pull-up resistor. The output then no longer presents +12 V at rest, but an open state. The SIR input in PO+ / NC ends up in permanent alarm. Two ways out: leave SW3 in the pulled-up position, or switch the input to PO- / NO.Programming the SIR menu
The interface consists of three seven-segment displays and four buttons: OK confirms, RETURN goes up one level, + and - scroll through the values.
Click to enlarge
OK for 2 seconds. The word MENU scrolls, then SIR appears. Confirm with OK.PO+ or PO- with + and -. Confirm.NC, normally closed, or NO, normally open. Confirm.S01 to S04. On a THE VOICE EXT, the expected value is S02.FL0 no strobe, FL1 for the strobe to accompany the tone. The strobe stays on until SIR is reset, even after the sound has stopped.RETURN until the displays go off. It also exits automatically after ten minutes without any action.Available tones
| Code | Tone | Duration | Sound level |
|---|---|---|---|
S01 |
Indoor, SI-MAX type | 10 min | 107 dB — 1.1 A |
S02 |
External NF C 48-265, 1400 to 1600 Hz. THE VOICE EXT default | 3 min | 107 dB — 1.2 A |
S03 |
SI-MAX no. 2, low consumption. Fault signalling | 10 min | 100 dB — 0.25 A |
S04 |
Fire NF S 32-001 | Continuous until reset | 92 dB — 0.6 A |
The tone chosen on SIR also sets the follow-up sound applied to the messages of inputs IN1 to IN4, when the siren follow-up parameter is set to SI1.
Reset
There are two reset levels. In both cases: cut the external power supply, disconnect the battery, then reconnect while holding a button down.
| Button held | Scope |
|---|---|
RETURN | Erases the recorded messages only |
OK | Full return to factory programming: messages, options and input trigger modes |
The characters rotating on the displays confirm that the reset has been taken into account.
Common pitfalls
S01 is the indoor tone, timed at 10 min. On an EXT, the expected value is S02: compliant with NF C 48-265 and timed at 3 min. An EXT left on S01 sounds for ten minutes with a non-compliant tone.PO+ / NC, the input requires a clean +12 V at rest. Without a pull-up, it stays high-impedance, a state read as an alarm: the siren sounds as soon as it is powered up. Restore the pull-up at the panel, or switch to PO- / NO.SIR reference floats. Triggering becomes erratic and false triggers appear on electrical interference.FL1, the strobe stays on until the input is reset (SIR), whereas the sound stops after 3 min. The strobe only goes off after acknowledgement at the panel.OFF, the siren reports a battery fault at the daily test. Set DIP 3 to ON. Check at the same time that the power supply can handle the 2 A drawn in alarm: the battery's energy reserve is no longer there to absorb the peak.SIR on a slave to mirror the master's trigger has the opposite effect.PO+, threshold > 3 V) or to its absence (PO-, threshold < 2 V).NC triggers when the rest condition disappears, NO when it appears. Always combine it with the polarity.Source: ATLS installation manual — THE VOICE-INT / THE VOICE-EXT, reference NOTINS0FR000065 (in French).