On a Honeywell Galaxy Dimension, keypads and expansion modules share an RS485 bus, called the line or AB bus.

Each device on it has an address, usually set on its board with a rotary switch. A wrong or duplicate address, and the panel does not see it.

This guide applies to the GD-48, GD-96, GD-264 and GD-520, with Mk7 and Mk8 keypads. The Galaxy Flex has its own address table.

⚡
The essentials in 30 seconds
  • Address: rotary switch 0 to F, set with the power off. The TouchCenter asks for it on screen.
  • Unique: two keypads on the same line never share an address, nor do two RIOs. A keypad and a RIO can use the same digit.
  • Line 1: RIO addresses 0 and 1 are taken by the board, keypad addresses B to E by the communication modules fitted.
  • Wireless: an RF Portal turns free RIO addresses into virtual RIOs.
  • Bus: daisy-chained, 680 Ω across A and B of the last module.
  • Adding: in installer mode, then the module is registered when you leave that mode.
  • Checking: RIO indicator light and option 61, Diagnostics.

The principle

1
One rotary switch per device
Mk7 and Mk8 keypads, KeyProx, RIO and Smart RIO EN have a 16-position rotary switch, 0 to 9 then A to F. Set it with the power off: a change only takes effect when the device is powered up again.
2
An address that is valid and unique within its family
Keypads, RIOs and MAX or DCM readers form three families, each with its own address range, which depends on the panel model and the line. Two RIOs at the same address: the second is not recognised. A RIO at 2 and a keypad at 2 on the same line, however, coexist.
3
The panel registers when you leave installer mode
A new device is taken into account when the system is powered up, or when you leave installer mode. The keypad then shows the number of modules added.
!
Loss of communication = tamper
The panel constantly monitors every module on the bus. A module that stops responding triggers a tamper alarm, logged as MANQUANT+ (missing) in the event log, then MANQUANT- when communication returns.

A real line: panel, RIO, keypad

A typical daisy-chained line: the panel, a RIO, then an Mk7 keypad, the last module, which carries the end of line. Turn a switch to see what each position gives, or trigger a fault. Positions are read for line 1 of a GD-264.

RIO switch2 · RIO 102
RIO zones1021 to 1028
Keypad switch0 · keypad 10
RIO LED10.1 s / 0.9 s

Normal: the panel communicates over A and B with the RIO and the keypad. RIO LED1: one 0.1 s flash per second.

Line 1 of a Galaxy Dimension daisy-chained: panel terminal block, cable, RIO, cable, Mk7 keypad and its 680 ohm end-of-line resistor Galaxy Dimension panel AUX1 (F4) Supply RIO 100 and 101 on the board Line 1 B1 A1 GND +12V Screen to chassis RIO 1 2 3 4 B A − + − + S LINE E/E SLAVE LED1 C 0 4 8 SW1 A=10 B=11 C=12 D=13 E=14 F=15 1 2 3 4 5 6 7 8 Mk7 keypad Baselink V6.00 08:58 MAR 22 NOV 1 2 3 A 4 5 6 B 7 8 9 ent * 0 # esc Keypad circuit board 0 4 8 C Rotary switch B A + − 680 Ω
+12 V 0 V A B Data exchange No power Break 680 Ω Shielded cable End of line: LK3 or LK5 link on the board, 680 Ω at the last module. SW1: RIO rotary switch, A = 10 to F = 15. LED1: RIO communication indicator light. E/E, SLAVE: RIO links, fitted.

Valid addresses

The number of lines depends on the model: one on the GD-48, two on the GD-96 and GD-264, four on the GD-520.

Line Valid addresses
GD-48
Line 1Mk7, Mk8: 0 to 2, B to F
KeyProx: 0 to 2
RIO: 2 to 5
GD-96
Line 1Mk7, Mk8: 0 to 2, B to F
KeyProx: 0 to 2
RIO: 2 to 5
Line 2Mk7, Mk8: 0 to 6, F
KeyProx: 0 to 3
RIO: 0 to 5
GD-264
Line 1Mk7, Mk8: 0 to 2, B to F
KeyProx: 0 to 2
RIO: 2 to 9, A to F
Line 2Mk7, Mk8: 0 to 6, F
KeyProx: 0 to 3
RIO: 0 to 9, A to F
GD-520
Line 1Mk7, Mk8: 0 to 2, B to F
KeyProx: 0 to 2
RIO: 2 to 9, A to F
Lines 2, 3 and 4Mk7, Mk8: 0 to 6, F
KeyProx: 0 to 6
RIO: 0 to 9, A to F
  • RIO: this column also applies to the Smart RIO EN and the Galaxy PSU, which each take a RIO address.
  • Line 1: RIO addresses 0 and 1 belong to the two RIOs on the board, so the first external RIO is at 2.
  • TouchCenter: same addresses as the KeyProx, only one per line.
  • GD-96, line 2: the installation manual gives 0 to 2 and B to F for keypads, the Honeywell training material 0 to 6 and F. The second reading agrees with the KeyProx addresses (0 to 3). Addresses 0, 1, 2 and F work in both cases.

Maximum numbers

Model Maximum
GD-48Keypads: 8, including 3 KeyProx and 1 TouchCenter
RIO: 4
GD-96Keypads: 16, including 7 KeyProx and 2 TouchCenter
RIO: 10
GD-264Keypads: 16, including 7 KeyProx and 2 TouchCenter
RIO: 31
GD-520Keypads: 32, including 24 KeyProx and 4 TouchCenter
RIO: 63

The RIOs counted are external RIOs, Smart RIO EN included, in addition to the two RIOs on the board. On the GD-264 and GD-520, the last RIO is only possible with switch SW3-8 set to ON (see below).

Keypads on line 1

On line 1, four keypad addresses are also used by the communication modules. They are only free if the corresponding module is not fitted.

Keypad address Taken by
BEthernet module, for its virtual keypad
CISDN module
DExternal RS232 module
EExternal Telecom module
FMaintenance address, can take an installer keypad

Only standard keypads on addresses B to E. These four modules only connect to line 1.

ℹ️
KeyProx: one address for two
The keypad and its badge reader share the switch address. It must therefore be valid for a keypad and for a MAX reader. For the reader to work, enable MAX mode (option 63.2.1). MAX addressing (option 63.2.2) is not needed.
ℹ️
RF Portal: wireless takes RIO addresses
  • The antenna: its switch gives it an address in its own family, 0 to F on each line.
  • Virtual RIOs: when it is detected, the panel turns the first two free RIO addresses, after the wired RIOs, into wireless RIOs of 8 zones each.
  • No link: the antenna address says nothing about the virtual RIO addresses. An antenna at 100 can give RIOs 102 and 103, or 200 and 205.
  • Setting: option 51.60.1 (Adresse RF, RF address) to enable a virtual RIO address or return it to wired use. Three at most per antenna.
ℹ️
RF RIO: up to four addresses
The RF RIO switch gives its base address. It can occupy the next three: base 2, then 3, 4 and 5. Only the base is active from the factory. Reserve these addresses before placing other RIOs.
💡
GD-264 and GD-520: freeing address 1
Switch 8 of SW3 moves RIO 1 on the board to line 0. An external RIO can then take address 1 on line 1, giving 15 external RIOs on that line. Factory setting: OFF. No effect on other models. Set it before powering up, and only if you need every address or to replace a Galaxy 512 that already has a Smart RIO at 1.

Reading a zone or keypad number

A zone has a four-digit number: the line, the RIO address in two digits, then the zone from 1 to 8 on that RIO. Outputs follow the same rule, from 1 to 4. In this number, switch positions A to F become 10 to 15.

Reference Numbers
Zone 3057Line 3, RIO 05, zone 7
Zone 4136Line 4, RIO 13 (switch on D), zone 6
RIO on 2, line 1Zones 1021 to 1028
Outputs 1021 to 1024
RIO on C, line 1RIO 112, zones 1121 to 1128
Board RIOs, SW3-8 OFF
RIO 0Zones 1001 to 1008
Outputs 1001 to 1004
RIO 1Zones 1011 to 1018
Outputs 1011 to 1014
SW3-8 ON
RIO 1Zones 0011 to 0018
Outputs 0011 to 0014

A keypad has a two-digit number: the line, then its position. Positions B to F become 5 to 9.

Line Keypad numbers
Line 110, 11, 12 (positions 0 to 2)
15 to 19 (positions B to F)
Line 220 to 26 (positions 0 to 6)
29 (position F)
Lines 3 and 430 to 36 and 39
40 to 46 and 49

In the event log, a keypad appears as K10: K for keypad, then the line (1) and the address (0).

Wiring the bus

A keypad or a RIO takes four wires: A, B, +12V and 0V. On the board, line 1 comes out on B1 A1 GND +12V, line 2 on B2 A2 GND +12V. The TouchCenter takes A on its G terminal and B on Y.

Rule Requirement
Topology
LayoutDaisy chain: A to A, B to B, from one module to the next. No spurs, no star.
End of line680 Ω across A and B of the last module.
Panel endThe end of line is on the board, via a link (LK3 or LK5) that must stay fitted.
Two runsRemove the line link. 680 Ω at the end of each run.
Length1 km maximum per line, all runs included.
Cable
TypeShielded twisted pair (reference W002), for example CAT5, CAT5e or 0.8 mm screened pair (Belden 8723).
ShieldingTo the panel chassis, via a standoff and a P-clip. Continuous screen, connected at one point only.
SharingOnly one bus per cable. Never a loudspeaker in the same cable.
Routing30 cm from other cables if possible, 5 m maximum in parallel.
Power supply
Voltage10.5 V minimum at the module, 12.5 V recommended.
Remote power suppliesNever in parallel with the panel. Do not connect their +12 V to the panel's.
0 VCommon to all power supplies and the panel.
NF&A2P 3 shields16 zones maximum per auxiliary power output, i.e. two RIOs. A Smart RIO, with its two outputs, therefore powers four at most.
!
LK3 or LK5: read the board
The manual's text assigns LK3 to line 1 and LK5 to line 2. Its drawing of the board shows the opposite. Before removing a link for a second run, read the screen-printed marking next to it.
  • GD-520: lines 3 and 4 come from the RS485 expansion module (A3 B3 A4 B4). Its links LK1 and LK2 provide the built-in ends of line. This module also turns a GD-264 into a GD-520.
  • Each line its own way: one line can have one run and the other two.
  • RIO, Smart RIO EN and Galaxy PSU: the SLAVE (ESCLAVE) and E/E links must be fitted for normal operation.

What each device draws

Device Current at 12 V
RIO40 mA (10.5 to 16 V)
30 mA with no load
RF RIO55 mA (10.5 to 16 V)
Mk7 keypad35 mA at rest
70 mA backlit
90 mA maximum in alarm
KeyProx Mk775 mA at rest
90 mA backlit
130 mA maximum in alarm
TouchCenter105 mA at rest

Far from the panel, voltage drop in the cable can take the supply below the minimum. In that case, power the module from a remote power supply, or replace the RIO with a Smart RIO EN, which has its own power supply.

Adding and removing a module

A keypad or a RIO can only be added in installer mode. Access to this mode must first be authorised by a level 3.6 user (option 48.1.1, key 1). The installer code is then entered within five minutes.

Adding

1
Set the address, power off
Choose a valid, free address on the line, then turn the rotary switch. On the keypad, it is on the board: separate the front panel from the base.
2
Enter installer mode
All tampers are disabled. The home screen shows Mode Installateur (installer mode).
3
Connect the module
A and B in parallel on the keypad bus, then + and − to a power supply. Last module on the line: 680 Ω across A and B.
4
Leave installer mode
Go back to the home screen, enter the installer code, then esc.
✓
Read the message
Keypad: 1 MOD. AJOUTE (1 module added), then esc.
KeyProx: 2 MOD AJOUTE (2 modules added), a keypad and a MAX reader.
RIO: XX modul ajoute (XX modules added), key A or B to view and confirm.
!
AUCUN MOD AJOUTE (no module added): the module is not seen
This message, no message at all, or a module missing from the list all mean the same thing: it is not communicating with the panel, or its address is already taken. Check the wiring and the address.

The zones of an added RIO are set to 03 = Immédiate (Immediate) from the factory. Each one is wired in double EOL, 1 kΩ in series and 1 kΩ across the contact.

The TouchCenter, addressed on screen

  • First power-up: it asks for a bus address. Give a valid, free keypad address on its line. From the factory, it offers 1.
  • Changing the address: power it up again, wait five seconds, then touch the Console mode button and ent.
  • Registration: when the panel is powered up again, or when leaving installer mode if another keypad is already in service.

Removing

1
Disconnect in installer mode
Enter installer mode, then disconnect the module.
2
Leave installer mode
The keypad shows 1 MOD. MANQUANT (1 module missing). Key A or B: CLAVIER XX (keypad XX) and *=SUPPRIMER (*=delete).
✓
Confirm with the star key
One press of * per module, then ent if a warning asks for it. A KeyProx counts as two (2 MOD MANQUANT): press twice. The panel then shows the number of modules before and after.
ℹ️
What prevents leaving installer mode
  • Tamper: a module or a zone is in tamper.
  • Missing module: it has not been deleted with *.
  • Door open: a door controlled by a MAX reader. Exit waits for it to close.
  • Power supply: a power supply, fuse or battery fault, or a battery that cannot hold the standby time set in option 51.37.
  • esc key: during these checks, it cancels the exit and the panel stays in installer mode.

Checking and troubleshooting

The RIO indicator light

The red LED1 light on the RIO shows the state of its communication with the panel.

Flashing Meaning
0.1 s on, 0.9 s offNormal communication
OffNo power
1.5 s on, 1.5 s offRIO not configured in the system
0.2 s on, 0.2 s offCommunication lost
0.9 s on, 0.1 s offVery poor communication

From the keypad

  • Option 23, Système (System): panel type, number of modules present (board RIOs included), keypads installed and communication modules. Compare with what is fitted.
  • Option 61, Diagnostics, Temps réel (Real time): DIAG.CLAVIER (keypad diagnostics) gives keypad communication quality. DIAG. RIO gives the voltage, version and communication of each RIO. DIAG. ALIM. (power supply diagnostics) adds current, fuses and battery of the power supplies.
  • Keypad self-test: power it up again while holding ent. It first shows its address, then tests the buzzer, light and keys, about four seconds per test. Cut and restore power to exit.

Common faults

!
Address changed, nothing changes
The switch was turned with the power on. Cut and restore power to the module.
!
Keypad not seen at B, C, D or E on line 1
The address belongs to an installed Ethernet, ISDN, RS232 or Telecom module. Choose another address.
!
KeyProx not seen on line 1
It only accepts 0, 1 or 2 there.
!
Wired RIO not seen after an RF Portal
Its address may have become a virtual RIO. An unused virtual address can be returned to wired use in option 51.60.1. Otherwise, choose another address.
!
Poor or intermittent communication
Check the bus rules: daisy chain, 680 Ω at the ends only, shield to chassis at one point, cable not shared.
!
An entire line silent
Check its fuse: AUX1 (F4) for line 1 and RIO 0, AUX2 (F3) for line 2 and RIO 1. In DIAG. ALIM., a 3 to the right of the current indicates F4 has failed, a 4 indicates F3.
!
Distant module, low voltage
Read its voltage in DIAG. RIO. Below 10.5 V, power it locally.

To check on site

  • The marking of the end-of-line link for each line, on the board's screen printing.
  • The position of each switch, noted before closing the enclosures.
  • The communication modules present on line 1, before placing a keypad at B to E.
  • The addresses an RF RIO could take, and those already turned into virtual RIOs by an RF Portal.

Sources: Galaxy Dimension installation manual (Honeywell), RS485 bus, peripherals, keypads, options 23 and 61 · Galaxy Dimension BASIC and ADVANCED technical training (Honeywell), peripheral addressing and RF Portal · Galaxy Dimension overview (Honeywell), capacities.

Glossary
Line (AB bus)
RS485 bus linking the panel to its keypads and modules. Its two data wires are called A and B.
RIO
Remote input/output module (C072): 8 zones and 4 outputs on the bus.
Smart RIO EN
Power supply with a built-in RIO, 8 zones and 4 outputs. It is addressed like a RIO.
Virtual RIO
RIO address taken by an RF Portal for 8 wireless zones. No module is fitted at this address.
KeyProx
Mk7 keypad with a proximity badge reader. The panel sees it as a keypad and a MAX reader.
TouchCenter
Touchscreen keypad, only one per line. Its keypad address is set on screen.
Rotary switch
16-position rotary switch (0 to 9, A to F) that sets a device's address.
680 Ω end of line
Resistor fitted across A and B at each end of the bus. At the panel end, a link on the board replaces it.
Installer mode
The panel's programming mode. Tampers are disabled and modules are added or removed in it.