Galaxy Dimension: addressing RIOs and keypads on the bus
5 November 2026 · Theo
FRLire cette fiche en françaisOn a Honeywell Galaxy Dimension, keypads and expansion modules share an RS485 bus, called the line or AB bus.
Each device on it has an address, usually set on its board with a rotary switch. A wrong or duplicate address, and the panel does not see it.
This guide applies to the GD-48, GD-96, GD-264 and GD-520, with Mk7 and Mk8 keypads. The Galaxy Flex has its own address table.
- Address: rotary switch 0 to F, set with the power off. The TouchCenter asks for it on screen.
- Unique: two keypads on the same line never share an address, nor do two RIOs. A keypad and a RIO can use the same digit.
- Line 1: RIO addresses 0 and 1 are taken by the board, keypad addresses B to E by the communication modules fitted.
- Wireless: an RF Portal turns free RIO addresses into virtual RIOs.
- Bus: daisy-chained, 680 Ω across A and B of the last module.
- Adding: in installer mode, then the module is registered when you leave that mode.
- Checking: RIO indicator light and option 61, Diagnostics.
The principle
MANQUANT+ (missing) in the event log, then MANQUANT- when communication returns.A real line: panel, RIO, keypad
A typical daisy-chained line: the panel, a RIO, then an Mk7 keypad, the last module, which carries the end of line. Turn a switch to see what each position gives, or trigger a fault. Positions are read for line 1 of a GD-264.
Normal: the panel communicates over A and B with the RIO and the keypad. RIO LED1: one 0.1 s flash per second.
Valid addresses
The number of lines depends on the model: one on the GD-48, two on the GD-96 and GD-264, four on the GD-520.
| Line | Valid addresses |
|---|---|
| GD-48 | |
| Line 1 | Mk7, Mk8: 0 to 2, B to F KeyProx: 0 to 2 RIO: 2 to 5 |
| GD-96 | |
| Line 1 | Mk7, Mk8: 0 to 2, B to F KeyProx: 0 to 2 RIO: 2 to 5 |
| Line 2 | Mk7, Mk8: 0 to 6, F KeyProx: 0 to 3 RIO: 0 to 5 |
| GD-264 | |
| Line 1 | Mk7, Mk8: 0 to 2, B to F KeyProx: 0 to 2 RIO: 2 to 9, A to F |
| Line 2 | Mk7, Mk8: 0 to 6, F KeyProx: 0 to 3 RIO: 0 to 9, A to F |
| GD-520 | |
| Line 1 | Mk7, Mk8: 0 to 2, B to F KeyProx: 0 to 2 RIO: 2 to 9, A to F |
| Lines 2, 3 and 4 | Mk7, Mk8: 0 to 6, F KeyProx: 0 to 6 RIO: 0 to 9, A to F |
- RIO: this column also applies to the Smart RIO EN and the Galaxy PSU, which each take a RIO address.
- Line 1: RIO addresses 0 and 1 belong to the two RIOs on the board, so the first external RIO is at 2.
- TouchCenter: same addresses as the KeyProx, only one per line.
- GD-96, line 2: the installation manual gives 0 to 2 and B to F for keypads, the Honeywell training material 0 to 6 and F. The second reading agrees with the KeyProx addresses (0 to 3). Addresses 0, 1, 2 and F work in both cases.
Maximum numbers
| Model | Maximum |
|---|---|
| GD-48 | Keypads: 8, including 3 KeyProx and 1 TouchCenter RIO: 4 |
| GD-96 | Keypads: 16, including 7 KeyProx and 2 TouchCenter RIO: 10 |
| GD-264 | Keypads: 16, including 7 KeyProx and 2 TouchCenter RIO: 31 |
| GD-520 | Keypads: 32, including 24 KeyProx and 4 TouchCenter RIO: 63 |
The RIOs counted are external RIOs, Smart RIO EN included, in addition to the two RIOs on the board. On the GD-264 and GD-520, the last RIO is only possible with switch SW3-8 set to ON (see below).
Keypads on line 1
On line 1, four keypad addresses are also used by the communication modules. They are only free if the corresponding module is not fitted.
| Keypad address | Taken by |
|---|---|
| B | Ethernet module, for its virtual keypad |
| C | ISDN module |
| D | External RS232 module |
| E | External Telecom module |
| F | Maintenance address, can take an installer keypad |
Only standard keypads on addresses B to E. These four modules only connect to line 1.
63.2.1). MAX addressing (option 63.2.2) is not needed.- The antenna: its switch gives it an address in its own family, 0 to F on each line.
- Virtual RIOs: when it is detected, the panel turns the first two free RIO addresses, after the wired RIOs, into wireless RIOs of 8 zones each.
- No link: the antenna address says nothing about the virtual RIO addresses. An antenna at 100 can give RIOs 102 and 103, or 200 and 205.
- Setting: option
51.60.1(Adresse RF, RF address) to enable a virtual RIO address or return it to wired use. Three at most per antenna.
SW3 moves RIO 1 on the board to line 0. An external RIO can then take address 1 on line 1, giving 15 external RIOs on that line. Factory setting: OFF. No effect on other models. Set it before powering up, and only if you need every address or to replace a Galaxy 512 that already has a Smart RIO at 1.Reading a zone or keypad number
A zone has a four-digit number: the line, the RIO address in two digits, then the zone from 1 to 8 on that RIO. Outputs follow the same rule, from 1 to 4. In this number, switch positions A to F become 10 to 15.
| Reference | Numbers |
|---|---|
| Zone 3057 | Line 3, RIO 05, zone 7 |
| Zone 4136 | Line 4, RIO 13 (switch on D), zone 6 |
| RIO on 2, line 1 | Zones 1021 to 1028 Outputs 1021 to 1024 |
| RIO on C, line 1 | RIO 112, zones 1121 to 1128 |
| Board RIOs, SW3-8 OFF | |
| RIO 0 | Zones 1001 to 1008 Outputs 1001 to 1004 |
| RIO 1 | Zones 1011 to 1018 Outputs 1011 to 1014 |
| SW3-8 ON | |
| RIO 1 | Zones 0011 to 0018 Outputs 0011 to 0014 |
A keypad has a two-digit number: the line, then its position. Positions B to F become 5 to 9.
| Line | Keypad numbers |
|---|---|
| Line 1 | 10, 11, 12 (positions 0 to 2) 15 to 19 (positions B to F) |
| Line 2 | 20 to 26 (positions 0 to 6) 29 (position F) |
| Lines 3 and 4 | 30 to 36 and 39 40 to 46 and 49 |
In the event log, a keypad appears as K10: K for keypad, then the line (1) and the address (0).
Wiring the bus
A keypad or a RIO takes four wires: A, B, +12V and 0V. On the board, line 1 comes out on B1 A1 GND +12V, line 2 on B2 A2 GND +12V. The TouchCenter takes A on its G terminal and B on Y.
| Rule | Requirement |
|---|---|
| Topology | |
| Layout | Daisy chain: A to A, B to B, from one module to the next. No spurs, no star. |
| End of line | 680 Ω across A and B of the last module. |
| Panel end | The end of line is on the board, via a link (LK3 or LK5) that must stay fitted. |
| Two runs | Remove the line link. 680 Ω at the end of each run. |
| Length | 1 km maximum per line, all runs included. |
| Cable | |
| Type | Shielded twisted pair (reference W002), for example CAT5, CAT5e or 0.8 mm screened pair (Belden 8723). |
| Shielding | To the panel chassis, via a standoff and a P-clip. Continuous screen, connected at one point only. |
| Sharing | Only one bus per cable. Never a loudspeaker in the same cable. |
| Routing | 30 cm from other cables if possible, 5 m maximum in parallel. |
| Power supply | |
| Voltage | 10.5 V minimum at the module, 12.5 V recommended. |
| Remote power supplies | Never in parallel with the panel. Do not connect their +12 V to the panel's. |
| 0 V | Common to all power supplies and the panel. |
| NF&A2P 3 shields | 16 zones maximum per auxiliary power output, i.e. two RIOs. A Smart RIO, with its two outputs, therefore powers four at most. |
- GD-520: lines 3 and 4 come from the RS485 expansion module (
A3B3A4B4). Its linksLK1andLK2provide the built-in ends of line. This module also turns a GD-264 into a GD-520. - Each line its own way: one line can have one run and the other two.
- RIO, Smart RIO EN and Galaxy PSU: the
SLAVE(ESCLAVE) andE/Elinks must be fitted for normal operation.
What each device draws
| Device | Current at 12 V |
|---|---|
| RIO | 40 mA (10.5 to 16 V) 30 mA with no load |
| RF RIO | 55 mA (10.5 to 16 V) |
| Mk7 keypad | 35 mA at rest 70 mA backlit 90 mA maximum in alarm |
| KeyProx Mk7 | 75 mA at rest 90 mA backlit 130 mA maximum in alarm |
| TouchCenter | 105 mA at rest |
Far from the panel, voltage drop in the cable can take the supply below the minimum. In that case, power the module from a remote power supply, or replace the RIO with a Smart RIO EN, which has its own power supply.
Adding and removing a module
A keypad or a RIO can only be added in installer mode. Access to this mode must first be authorised by a level 3.6 user (option 48.1.1, key 1). The installer code is then entered within five minutes.
Adding
Mode Installateur (installer mode).+ and − to a power supply. Last module on the line: 680 Ω across A and B.esc.1 MOD. AJOUTE (1 module added), then esc.KeyProx:
2 MOD AJOUTE (2 modules added), a keypad and a MAX reader.RIO:
XX modul ajoute (XX modules added), key A or B to view and confirm.The zones of an added RIO are set to 03 = Immédiate (Immediate) from the factory. Each one is wired in double EOL, 1 kΩ in series and 1 kΩ across the contact.
The TouchCenter, addressed on screen
- First power-up: it asks for a bus address. Give a valid, free keypad address on its line. From the factory, it offers 1.
- Changing the address: power it up again, wait five seconds, then touch the Console mode button and
ent. - Registration: when the panel is powered up again, or when leaving installer mode if another keypad is already in service.
Removing
1 MOD. MANQUANT (1 module missing). Key A or B: CLAVIER XX (keypad XX) and *=SUPPRIMER (*=delete).* per module, then ent if a warning asks for it. A KeyProx counts as two (2 MOD MANQUANT): press twice. The panel then shows the number of modules before and after.- Tamper: a module or a zone is in tamper.
- Missing module: it has not been deleted with
*. - Door open: a door controlled by a MAX reader. Exit waits for it to close.
- Power supply: a power supply, fuse or battery fault, or a battery that cannot hold the standby time set in option
51.37. - esc key: during these checks, it cancels the exit and the panel stays in installer mode.
Checking and troubleshooting
The RIO indicator light
The red LED1 light on the RIO shows the state of its communication with the panel.
| Flashing | Meaning |
|---|---|
| 0.1 s on, 0.9 s off | Normal communication |
| Off | No power |
| 1.5 s on, 1.5 s off | RIO not configured in the system |
| 0.2 s on, 0.2 s off | Communication lost |
| 0.9 s on, 0.1 s off | Very poor communication |
From the keypad
- Option 23, Système (System): panel type, number of modules present (board RIOs included), keypads installed and communication modules. Compare with what is fitted.
- Option 61, Diagnostics, Temps réel (Real time):
DIAG.CLAVIER(keypad diagnostics) gives keypad communication quality.DIAG. RIOgives the voltage, version and communication of each RIO.DIAG. ALIM.(power supply diagnostics) adds current, fuses and battery of the power supplies. - Keypad self-test: power it up again while holding
ent. It first shows its address, then tests the buzzer, light and keys, about four seconds per test. Cut and restore power to exit.
Common faults
51.60.1. Otherwise, choose another address.AUX1 (F4) for line 1 and RIO 0, AUX2 (F3) for line 2 and RIO 1. In DIAG. ALIM., a 3 to the right of the current indicates F4 has failed, a 4 indicates F3.DIAG. RIO. Below 10.5 V, power it locally.To check on site
- The marking of the end-of-line link for each line, on the board's screen printing.
- The position of each switch, noted before closing the enclosures.
- The communication modules present on line 1, before placing a keypad at B to E.
- The addresses an RF RIO could take, and those already turned into virtual RIOs by an RF Portal.
Sources: Galaxy Dimension installation manual (Honeywell), RS485 bus, peripherals, keypads, options 23 and 61 · Galaxy Dimension BASIC and ADVANCED technical training (Honeywell), peripheral addressing and RF Portal · Galaxy Dimension overview (Honeywell), capacities.