Battery life
How long the battery keeps the control panel and its devices running when mains power fails, and what capacity to plan for the required time.
Estimated backup time
–
Enter at least one consumption.
- Minimum capacity for 36 h
- –
- Maximum current for 17 Ah over 36 h
- 401 mA
How it is calculated
Only 85% of the battery capacity is counted: that is the usable power Vanderbilt uses for SPC control panels.
- Backup time = 0.85 × capacity (Ah) ÷ consumption (A)
- Minimum capacity = consumption (A) × time (h) ÷ 0.85
- Maximum current = 0.85 × capacity (Ah) ÷ time (h)
Two batteries count as the sum of their capacities. If the consumption exceeds what the power supply can deliver, you need an expander with its own power supply.
Standby and recharge times
| Requirement | Standby | Recharge time |
|---|---|---|
| EN 50131 grade 2 | 12 h | 72 h |
| INCERT | 24 h | 24 h |
| EN 50131 grade 3, VdS-B | 30 h | 24 h |
| NF&A2P grade 2 (EN + PSTN) | 36 h | 72 h |
| NF&A2P grade 3 (EN + PSTN), VdS-C | 60 h | 24 h |
The current consumption catalogue
45 devices, each with the document its standby current comes from. A device is missing? Suggest it, with its manual.
- Bosch ISC-BPR2-W1210 mA
PIR motion detector, 12 m · in standby and in alarm, at 12 V
- Bosch ISC-BPR2-WP1210 mA
PIR motion detector, 12 m, pet immune · in standby and in alarm, at 12 V
- Bosch ISC-BDL2-W12G10 mA
TriTech dual technology, 12 m · in standby and in alarm, at 12 V
- Bosch ISC-BDL2-W12GE10 mA
TriTech dual technology, 12 m · in standby and in alarm, at 12 V
- Bosch ISC-BDL2-WP12G10 mA
TriTech dual technology, 12 m, pet immune · in standby and in alarm, at 12 V
- Bosch ISC-BDL2-WP6G10 mA
TriTech dual technology, 6 m, pet immune · in standby and in alarm, at 12 V
- Honeywell IS30127 mA
PIR motion detector, 12 m · max 11 mA · typical, at 12 V
- Honeywell IS30167 mA
PIR motion detector, 16 m · max 11 mA · typical, at 12 V
- Honeywell DT8012F59 mA
dual technology, 12 m · max 14 mA · typical, at 12 V
- Honeywell DT8016F59 mA
dual technology, 16 m · max 14 mA · typical, at 12 V
- Optex SL-200QDM26 mA
4-beam infrared barrier, 60 m, transmitter + receiver · max 40 mA · transmitter 11 mA, receiver 15 mA, at 10.5 to 30 V DC
- Optex SL-350QDM26 mA
4-beam infrared barrier, 100 m, transmitter + receiver · max 40 mA · transmitter 11 mA, receiver 15 mA, at 10.5 to 30 V DC
- Optex SL-650QDM30 mA
4-beam infrared barrier, 200 m, transmitter + receiver · max 43 mA · transmitter 15 mA, receiver 15 mA, at 10.5 to 30 V DC
- Optex SL-200QDP17 mA
4-beam infrared barrier, 60 m, transmitter + receiver · max 24 mA · transmitter 6 mA, receiver 11 mA, at 10.5 to 30 V DC
- Optex SL-350QDP17 mA
4-beam infrared barrier, 100 m, transmitter + receiver · max 24 mA · transmitter 6 mA, receiver 11 mA, at 10.5 to 30 V DC
- Optex SL-650QDP22 mA
4-beam infrared barrier, 200 m, transmitter + receiver · max 33 mA · transmitter 11 mA, receiver 11 mA, at 10.5 to 30 V DC
- ATLS THE VOICE EXT35 mA
outdoor siren · at 12 V without internal battery, 25 mA on its internal battery, up to 2 A in alarm without internal battery
- ATLS THE VOICE INT35 mA
indoor siren · at 12 V without internal battery, 25 mA on its internal battery, up to 2 A in alarm without internal battery
- SATEL INT-KLCD17 mA
keypad · max 101 mA
- SATEL INT-KLCDR60 mA
keypad · max 156 mA
- SATEL INT-KLCDL61 mA
keypad · max 147 mA
- SATEL INT-KLCDS33 mA
keypad · max 151 mA
- SATEL INT-KLCDK30 mA
keypad · max 110 mA
- SATEL INT-KLFR60 mA
keypad · max 110 mA
- Harmonia 228015 mA
keypad · max 50 mA · 35 mA more when backlit
- Harmonia 228115 mA
keypad · max 50 mA · 35 mA more when backlit
- Harmonia 2281E15 mA
keypad · max 50 mA · 35 mA more when backlit
- ACIE SU2200 mA
code keypad · 20 to 200 mA according to the manual: the high value is used to be safe
- SATEL INTEGRA 64 / 128 / 256 Plus130 mA
control panel main board · max 200 mA
- Harmonia 2650 / 2660 / 268045 mA
control panel board · 38 mA board only, 45 mA with inputs connected
- Harmonia 208022 mA
input/output module · 15 mA alone, 22 mA with inputs connected
- Harmonia 208122 mA
input/output module · 15 mA alone, 22 mA with inputs connected
- Harmonia 209012 mA
printer module · 6 mA more with the printer connected
- TIL TILLYS CUBE60 mA
UTL controller · typical at 13.5 V, up to 200 mA at start-up
- Aritech ATS1201E75 mA
expansion board · at 13.8 V
- Honeywell Galaxy RIO (C072)40 mA
expansion module
- Harmonia 3530H34 mA
communicator board · max 54 mA · 20 mA more while transmitting
- Harmonia 30570.5 mA
voice board
- Harmonia ME304 mA
intercom module
- Harmonia MH304 mA
intercom module
- Harmonia MH20030 mA
intercom module
- Pulsar AWZ52937 mA
relay module · per energised relay: count the relays energised at rest
- Finder 46.61, bobine 12 V DC40 mA
relay · coil energised
- Sewosy PLS122450 mA
signalling panel
- Harmonia 1031 / 10326 mA
signalling box · 6 mA per lit light, 0 mA when off: the quantity is the number of lit lights
Sources: SPC 3.11 (French manual), calculating the power required for the battery · Aritech ATSx500A (French manual), auxiliary current and battery capacity · SATEL INTEGRA Plus (French manual), current consumption