26 November 2026 · Theo

FRLire cette fiche en français
●○
Difficulty: Beginner
⏱️
Reading time: ~7 min

DLOADX is the SATEL software that programs INTEGRA control panels from a PC. It can be downloaded from the Software section.

This guide connects DLOADX to an INTEGRA 64 Plus, 128 Plus or 256 Plus panel: first locally, through the USB or RS-232 port on the board, then remotely over the network, with the ETHM-1 Plus Ethernet module.

⚡
The essentials in 30 seconds
  • Version: DLOADX 1.18.000 or later.
  • Opening the software: factory access code 1234, to be changed as soon as possible. Three wrong codes close the program.
  • Locally: USB mini-B or RS-232 cable, port selected in DLOADX, then on the keypad DOWNLOADING → DEMARR. DWNL-RS (start DWNL-RS) with the service code (12345 by default).
  • First contact: if the panel still has its factory identifiers, DLOADX offers new ones, which you accept or enter yourself.
  • Over the network: ETHM-1 Plus module connected to the panel's RS-232, CONNEX. DLOADX (DLOADX connection) option enabled, same CLÉ DLOADX (DLOADX key) on both sides, TCP port 7090 by default.
  • To finish: FIN DWNL-RS (end DWNL-RS). Otherwise, local programming stops on its own 255 minutes after DLOADX was last used.

Before you start

You need Details
The software DLOADX version 1.18.000 or later.
A USB cable USB mini-B socket on the panel board. The drivers can be downloaded from satel.eu.
Or an RS-232 cable RJ-type socket on the board, female DB-9 connector on the PC side. SATEL sells it ready-made, as the DB9F/RJ-KPL kit.
The service code 12345 by default.
Service access Open by default. Once the installation has been handed over, the administrator may have closed it (see below).
⚠️
Service access, set by the administrator

Programming is only possible if one of these conditions is met:

  • the ACCÈS PERMANENT DU SERVICE (permanent service access) option is enabled, which is the factory setting.
  • the ACCÈS PERMANENT DU DLOADX (permanent DLOADX access) option is enabled, also by default.
  • the administrator has opened temporary access with the ACCÈS DU SERVICE (service access) function, for a time in hours.

Standards require the administrator to restrict service access once the installation is complete. On a panel in use, you therefore often have to ask them to open this access.

Opening DLOADX

The program is protected by an access code. On first launch, the factory code is 1234: just click OK, without typing it.

  • Change this code as soon as possible.
  • Three wrong codes in a row close the program.

Not to be confused with the panel's service code, 12345 by default, which is entered on the keypad.

Connecting locally, over USB or RS-232

1
Connect the PC to the panel

Connect the PC to the USB mini-B port or to the RS-232 port (RJ socket) on the panel board.

Over USB, Windows detects a new device and starts installing the drivers. If it warns that the driver has not passed compatibility testing, continue anyway.

Connecting USB disables the panel's RS-232 port.

Diagram: the PC running DLOADX connected to the INTEGRA Plus panel board either by a USB cable to the USB mini-B socket, or by an RS-232 cable to the RJ socket, with a female DB-9 connector on the PC side. A connected USB cable disables the RS-232 port

Two sockets on the board, one cable at a time: a connected USB cable disables the RS-232. Click to enlarge.

The RS-232 cable connects the panel's RJ socket to a female DB-9 connector, pin to pin:

RS-232 lead wiring, panel RJ socket to PC female DB-9: pin 6 COM to 5 COM, pin 1 DSR to 4 DTR, pin 3 RTS to 8 CTS, pin 4 RXD to 3 TXD, pin 5 TXD to 2 RXD. Pin 2 of the RJ socket not wired. Ready-made cable: DB9F/RJ-KPL kit

Read each line from left to right: panel RJ pin, then PC DB-9 pin. The RX of one goes to the TX of the other.

2
Select the port in DLOADX

In DLOADX, open the Configuration window with its toolbar button. Select the PC port the panel is connected to, then OK.

3
Start local programming from the keypad
  1. On one of the panel's keypads, enter the service code (12345 by default) and confirm.
  2. Use the arrows to scroll down to DOWNLOADING and open it.
  3. On DEMARR. DWNL-RS, confirm.
On the panel keypad: service code 12345 then confirm, scroll down with the arrows to DOWNLOADING, then confirm DEMARR. DWNL-RS. DLOADX connects. To finish: FIN DWNL-RS

Three keypad screens, from the service code to DEMARR. DWNL-RS. The same menu holds FIN DWNL-RS to finish.

4
Check the connection

An on-screen message confirms that communication is established. In DLOADX, the colour of the communication button shows the status:

  • green: ready to send data.
  • green to yellow: transfer in progress.
  • red: no communication with the panel.
  • grey: COM port disabled.
5
Finish

On the keypad: service code, DOWNLOADING → FIN DWNL-RS.

Without this command, the function stops on its own 255 minutes after DLOADX was last used.

💡
Free the RS-232 port

Stop local programming before the panel uses its RS-232 port with a modem, a GSM module, an INT-GSM or an ETHM-1 Plus, for example to program it remotely.

The INTEGRA and DLOADX identifiers

DLOADX only communicates with the panel in two cases:

  • The panel has its factory identifiers: the program offers new, randomly generated ones. You accept them or enter your own.
  • The identifiers are the same in the program and in the panel.
Identifier Purpose
INTEGRA identifier Identifies the panel and links it to its data file on the PC. 10 characters, digits or letters A to F. Two panels managed from the same PC must not share the same one.
DLOADX identifier Identifies the PC. 10 characters, digits or letters A to F. The panel only talks to the program that has the right one.

Where to program them:

  • On the keypad: service mode, CONFIGURATION MS (service mode configuration) → IDENT. INTEGRA (INTEGRA identifier) and IDENT. DLOADX (DLOADX identifier).
  • In DLOADX: the Mots passe et N° téléph. (passwords and phone numbers) window, in the Communication menu or with Ctrl+R.

Connecting over the network with the ETHM-1 Plus

Remotely, DLOADX goes through the ETHM-1 Plus (or ETHM-1) Ethernet module. The RS-232 ports of the panel and the module must be connected. Before you start, make sure local programming has been ended.

Diagram: the PC running DLOADX reaches over the network the ETHM-1 Plus module, connected to the RS-232 port of the INTEGRA Plus panel. TCP port 7090 and DLOADX key, the same in the module and in DLOADX. Panel: MODEM EXTERNE, MODEM ISDN/GSM/ETHM and RÉPONSE ETHM/GSM options. Module: CONNEX. DLOADX enabled, key, network, port

The ETHM-1 Plus module bridges the network and the panel's RS-232. The port and the key must be the same on both sides.

What needs to be set

Where Setting
Panel MODEM EXTERNE (external modem), MODEM ISDN/GSM/ETHM and RÉPONSE ETHM/GSM (ETHM/GSM answer) options enabled, in the telephone options.
ETHM-1 Plus module CONNEX. DLOADX option enabled, CLÉ DLOADX programmed, network parameters set, DLOADX TCP port (7090 by default).
DLOADX Mots passe et N° téléph. window (Ctrl+R): module address, port and key, identical to those in the module.

In DLOADX, the Connexion (connection) field in this window offers two sets of parameters:

  • LAN/WAN: you enter the Adresse serv. (server address), the Port and the Clé DLOADX yourself. The address can be an IP address or a domain name. If the module is not on the same local network as the PC, it must be public.
  • LAN: ETHM-1, Adresse n: DLOADX takes the module's settings, on the local network only. If the module gets its address from a DHCP server, it is not taken.

The DLOADX key encrypts the exchanges: 12 characters maximum, digits, letters or special characters.

Starting the connection from DLOADX

1
Choose the connection mode

First check, in the Mots passe et N° téléph. window, that the Connexion field has the right set of parameters.

Click the DLOADX communication button. In the menu that opens, choose TCP/IP : DLOADX -> ETHM, then:

  • LAN/WAN for a connection over the internet.
  • LAN on the local network.
2
Connect

Click Connect. in the window displayed. DLOADX shows a message confirming that communication is established.

Other ways to establish the connection

Who calls What you need
DLOADX calls the panel The method above. Over the internet, the panel must have a public IP address.
The panel calls DLOADX, started from the keypad The PC must have a public IP address. The panel can then only be programmed from this computer, which prevents programming without the owner's knowledge.
By SMS An INT-GSM module connected to the ETHM-1 Plus, and a public IP address for the PC.
Through the SATEL server No public address needed, for either the panel or the PC. DLOADX asks for the ETHM-1 ID assigned by the server, the module's MAC address and the DLOADX key.

Details of the module's own settings (IP address, DHCP, port, server) are in the ETHM-1 Plus manual.

If the connection fails

  • Different identifiers: the INTEGRA and DLOADX identifiers in the program must match those in the panel. Reprogram them if needed, on the keypad in CONFIGURATION MS or in DLOADX.
  • Service access closed: ask the administrator to enable permanent access or to open temporary access with ACCÈS DU SERVICE.
  • USB cable connected: it disables the RS-232 port. Unplug it to use the RS-232 or a module connected to it.
  • Over the network: first end local programming (FIN DWNL-RS), then check that the key and port are the same in the module and in DLOADX.

The keypad no longer accepts the service code

If the panel no longer handles its keypads or rejects the service code, the manual provides for starting service mode "from the pins":

  1. Power down the panel: mains first, then the battery.
  2. Fit the jumper on the RESET pins on the board.
  3. Power up again: battery first, then mains. The DIALER light flashes.
  4. Wait a few seconds for it to go out, then remove the jumper.

If DLOADX is open on a PC connected to the RS-232 port, the panel does not enter service mode: it is then programmed directly from the PC. The USB port is not used for this procedure.

The VERROU. DOWNLOADING (downloading lock) option prevents local programming started from the pins.

SATEL documentation: INTEGRA Plus programming manual (chapter 3) and INTEGRA Plus installer manual (connecting the computer), as well as the user manual for service access.

Frequently asked questions

What is the DLOADX access code?

1234 by default. On first launch, just click OK.

Change it as soon as possible. Three wrong codes close the program.

What is the service code of an INTEGRA panel?

12345 by default. It is entered on the panel keypad, not in DLOADX.

DLOADX over USB or RS-232?

  • USB: mini-B socket on the board, drivers on satel.eu. Connecting it disables the RS-232.
  • RS-232: RJ socket on the board, female DB-9 on the PC side, ready-made cable as the DB9F/RJ-KPL kit. It is the only one used when starting from the pins.

Can an INTEGRA be programmed remotely with DLOADX?

Yes, in three ways:

  • Over the network: with an ETHM-1 Plus or ETHM-1 module.
  • Over GPRS: with an INT-GSM module or a SATEL GSM module.
  • By modem: the panel's own or an external modem.

DLOADX won't connect to the panel: what should I check?

  1. The INTEGRA and DLOADX identifiers: the same in the program and in the panel.
  2. Service access: opened by the administrator.
  3. The USB cable: it disables the RS-232 port.
  4. Over the network: local programming ended, same key and same port on both sides.

How do I exit local programming?

On the keypad: service code, DOWNLOADING → FIN DWNL-RS.

Otherwise, it stops on its own 255 minutes after DLOADX was last used.

Glossary
DLOADX
SATEL PC software that programs INTEGRA panels, locally by cable or remotely.
Service code
Installer code, entered on the panel keypad to open service mode. 12345 by default.
DWNL-RS
Function in the DOWNLOADING menu that starts (DEMARR.) or stops (FIN) local programming with DLOADX.
ETHM-1 Plus
SATEL Ethernet module, connected to the panel's RS-232 port, used to program it over the network.
DLOADX key
Encryption key for exchanges between DLOADX and the module, 12 characters maximum. The same in the module and in the program.